116-397 AAAmgr Illegal Setting Area Coverage Threshold
When the setting value of the system data in the boot sequence, fulfilled any of the following
conditions. 720-061 (threshold B) <= 720-060 (threshold A)
•
If the value of Chain-Link 720-060 is lower than 720-061 a Fault will be detected.
•
As a Fault will be detected when the value of Chain-Link 720-060 is lower than 720-061, the value
of Chain-Link 720-060 must not be lower than 720-061.
Applicable Fault Code
•
116-397: Plain Total Color Judgment Threshold Value Settings Incorrect
Initial Actions
•
Power cycle the printer.
•
If the problem persists, perform the following procedure
Troubleshooting Procedure
Step
Actions and Questions
1.
Set the value of system data such that it conforms to the following relative value.
Chain-Link 720-061 (threshold B) > Chain-Link 720-060 (threshold A)
Note:
The value of Chain-Link 720-060 cannot be lower than that of 720-061.
Xerox Internal Use Only
.
Phaser 7100 Service Manual 2-357
Error Troubleshooting