Bypass Tray
REP 3.1 Bypass Tray Frame Assembly
PL 3.1.2
1.
Release latch A and open the Front Frame Assembly (PL 4.1.6).
2.
Remove 2 screws (silver, tapped, 10 mm) that secure the Bypass Tray Frame Assembly to the
printer.
3.
Remove the Bypass Tray Frame Assembly from the printer.
Xerox Internal Use Only
Service Parts Disassembly
s7100-255
Phaser 7100 Service Manual
s7100-088
4-69