2.4

Welding and earth return cables

Recommended copper cables with cross-sectional area are as follows:
FastMig M 320
FastMig M 420
FastMig M 520
In enclosed table are shown typical load capacities of rubber insulated copper cables, when
ambient temperature is 25 °C and lead temperature is 85 °C.
Cable
50 mm²
70 mm²
95 mm²
Do not overload welding cables due to voltage losses and heating.
! Always check the serviceability of the earth return cable and clamp. Ensure the metal
NOTE
surface to which the cable is connected is clean from metal oxide or paint. Check the connector to
EN
the power source is fastened correctly.
3.

OPERATION CONTROLS

3.1

Main switch I/O

When you turn the switch into I-position, pilot lamp H11 on the front face is illuminated and
the machine is ready for use.
Always turn the machine on and off with the mains switch, never use the mains plugs as a
NOTE!
switch.
3.2

Pilot lamps

The pilot lamps of the machine report the electric operation:
The green pilot lamp H11 when lit indicates that the machine is on and ready for use and it is
connected to the mains supply with the main switch in the I-position.
H12 indicates when lit that the thermal protection of the machine has been activated due to
over heating. The cooling fan will continue to run and cool the machine down and when the
lamp is off the machine is ready to weld.
3.3

Operation of cooling fan

In FastMig power sources there are two simultaneously operating fans.
• The fan is started for a moment when main switch is placed into position I.
• The fan will start during welding as the machine heats up and it will run for 1 to 10
minutes after the welding has stopped.
8
FastMig M 320, 420, 520
50 – 70 mm²
70 – 90 mm²
70 – 90 mm²
Duty cycle ED
100 %
60 %
285 A
370 A
355 A
460 A
430 A
560 A
Voltage loss / 10 m
30 %
520 A
0.35 V / 100 A
650 A
0.25 V / 100 A
790 A
0.18 V / 100 A