Safety Stop Response Timing - Kemppi A3 Integration Manual

Table of Contents

Advertisement

Touch response timing
Short circuit (touch)
Fast status output
TouchSensed
Symbol
Description
A
Fast status (hardware output) reaction
time
B
Touch signal function reaction time
Touch sensor off timing
A
TouchSensorOn
Touch sensor
Power on
RI
Symbol
Description
A
Control response time
B
Power-off cycle time (voltage drop time)
B
Min
Typical
Max
150
10
B
Voltage drop
Power off
Min
Typical
Max
3
25
30
© Kemppi Oy 2020

5.4.7 Safety stop response timing

System status
Welding system
Units
µs
Symbol
Description
ms
A
Hardware response time
B
Error setup time
C
Welding system stop time
Power source off time (arc off time)
Wire feed stop time
Touch sensor off time
D
ErrorNumber and Error signal
setup time
Units
ms
ms
21
A3 MIG Welder
A
B
C
D
OK
Error setup time
Operating
NO ERROR (0)
Min
Typical
L
ERROR
STOPPED
EMERGENCY S TOP (133)
Max
Units
500
µs
10
ms
10
ms
80
ms
30
ms
10
ms
R01

Advertisement

Table of Contents
loading