Function
Parameter Name
Code
P8-05
Acceleration time 3
P8-06
Deceleration time 3
P8-07
Acceleration time 4
P8-08
Deceleration time 4
P8-09
Jump frequency 1
P8-10
Jump frequency 2
P8-11
Frequency jump amplitude
Forward/Reverse rotation
P8-12
dead-zone time
P8-13
Reverse control
Running mode when set
P8-14
frequency lower than
frequency lower limit
P8-15
Droop control
Accumulative power-on time
P8-16
threshold
Accumulative running time
P8-17
threshold
P8-18
Startup protection
Frequency detection value
P8-19
(FDT1)
Frequency detection
P8-20
hysteresis (FDT hysteresis 1)
Detection range of frequency
P8-21
reached
Jump frequency during
P8-22
acceleration/deceleration
Frequency switchover point
P8-25
between acceleration time 1
and acceleration time 2
Frequency switchover point
P8-26
between deceleration time 1
and deceleration time 2
P8-27
Terminal JOG preferred
Setting Range
0.0–6500.0s
0.0–6500.0s
0.0–500.0s
0.0–6500.0s
0.00 Hz to maximum frequency
0.00 Hz to maximum frequency
0.00 Hz to maximum frequency
0.0–3000.0s
0: Enabled
1: Disabled
0: Run at frequency lower limit
1: Stop
2: Run at zero speed
0.00–10.00 Hz
0–65000 h
0–65000 h
0: No
1: Yes
0.00 Hz to maximum frequency
0.0%–100.0% (FDT1 level)
0.00–100% (maximum frequency)
0: Disabled1: Enabled
0.00 Hz to maximum frequency
0.00 to maximum frequency
0: Disabled1: Enabled
- 99 -
Function Code Table
Default
Property
Model
dependent
Model
dependent
Model
dependent
Model
dependent
0.00 Hz
0.00 Hz
0.00 Hz
0.0s
0
0
0.00 Hz
0 h
0 h
0
50.00 Hz
5.0%
0.0%
0
0.00 Hz
0.00 Hz
0

Advertisement