Advertisement

Description of Function Codes
Function Code
U0-58
It displays the phase Z counting of the current ABZ or UVW encoder. The value increases or
decreases by 1 every time the encoder rotates one revolution forwardly or reversely.
You can check whether the installation of the encoder is normal by viewing U0-58.
Function Code
U0-59
U0-60
It displays the current set frequency and running frequency. 100.00% corresponds to the AC
drive's maximum frequency (P0-10).
Function Code
U0-61
It displays the running state of the AC drive. The data format is listed in the following table:
Function Code
U0-62
It displays the current fault code.
Function Code
U0-63
Sent value of point-point communication
U0-64
Received value of point-point communication
It displays the data at point-point communication. U0-63 is the data sent by the master, and
U0-64 is the data received by the slave.
Function Code
U0-65
It displays the current setting torque upper limit.
Parameter Name
Phase Z counting
Parameter Name
Current set frequency
Current running frequency
Parameter Name
AC drive running state
Bit0
0: Stop
1: Forward
Bit1
2: Reverse
0: Constant
Bi2
U0-61
1: Accelerate
Bit3
2: Decelerate
0: Bus voltage normal
Bit4
1: Undervoltage
Name
Current fault code
Name
Name
Torque upper limit
-100.00%–100.00%
-100.00%–100.00%
- 246 -
I5300 User Manual
Display Range
0–65535
Display Range
Display Range
0–65535
Display Range
0–99
Display Range
-100.00%–100.00%
-100.00%–100.00%
Display Range
-200.00%–200.00%