Function Code Table
Function
Parameter Name
Code
P0-12
Frequency upper limit
P0-13
Frequency upper limit offset
P0-14
Frequency lower limit
P0-15
Carrier frequency
Carrier frequency
P0-16
adjustment with temperature
P0-17
Acceleration time 1
P0-18
Deceleration time 1
Acceleration/Deceleration
P0-19
time unit
Frequency offset of auxiliary
P0-21
frequency source for X and
Y operation
Frequency reference
P0-22
resolution
Retentive of digital setting
P0-23
frequency upon power
failure
Motor parameter group
P0-24
selection
Acceleration/Deceleration
P0-25
time base frequency
Base frequency for UP/
P0-26
DOWN modification during
running
Setting Range
Frequency lower limit (P0-14) to
maximum frequency (P0-10)
0.00 Hz to maximum frequency
(P0-10)
0.00 Hz to frequency upper limit
(P0-12)
0.5–16.0 kHz
0: No
1: Yes
0.00–650.00s (P0-19 = 2)
0.0–6500.0s (P0-19 = 1)
0–65000s (P0-19 = 0)
0.00–650.00s (P0-19 = 2)
0.0–6500.0s (P0-19 = 1)
0–65000s (P0-19 = 0)
0:1s
1: 0.1s
2: 0.01s
0.00 Hz to maximum frequency
(P0-10)
1: 0.1 Hz
2: 0.01 Hz
0: Not retentive
1: Retentive
0: Motor parameter group 1
1: Motor parameter group 2
2: Motor parameter group 3
3: Motor parameter group 4
0: Maximum frequency (P0-10)
1: Set frequency
2: 100 Hz
0: Running frequency
1: Set frequency
- 82 -
I5300 User Manual
Default
Property
50.00 Hz
0.00 Hz
0.00 Hz
Model
dependent
1
Model
dependent
Model
dependent
1
0.00 Hz
2
2
0
0
0