The swing amplitude is set in PB-00 and PB-01. When PB-01 is set to 0, the swing amplitude
is 0 and the swing frequency does not take effect.
Figure 6-30 Swing frequency control
Output
frequency (Hz)
Swing frequency
upper limit
Set frequency Fset
Swing frequency
lower limit
RUN
command
Function Code
Swing frequency
PB-00
setting mode
This parameter is used to select the base value of the swing amplitude.
0: Relative to the central frequency (P0-07 frequency source selection)
It is variable swing amplitude system. The swing amplitude varies with the central
frequency (set frequency).
1: Relative to the maximum frequency (P0-10 maximum output frequency)
It is fixed swing amplitude system. The swing amplitude is fixed.
Function Code
PB-01
PB-02
This parameter is used to determine the swing amplitude and jump frequency amplitude.
The swing frequency is limited by the frequency upper limit and frequency lower limit.
If relative to the central frequency (PB-00 = 0), the actual swing amplitude AW is the
calculation result of P0-07 (Frequency source selection) multiplied by PB-01.
If relative to the maximum frequency (PB-00 = 1), the actual swing amplitude AW is the
calculation result of P0-10 (Maximum frequency) multiplied by PB-01.
Jump frequency = Swing amplitude AW x PB-02 (Jump frequency amplitude).
If relative to the central frequency (PB-00 = 0), the jump frequency is a variable value.
If relative to the maximum frequency (PB-00 = 1), the jump frequency is a fxed value.
The swing frequency is limited by the frequency upper limit and frequency lower limit.
+Aw
-Aw
Textile kick frequency
= Aw x PB-02
Accelerate by
acceleration time
Parameter Name
Parameter Name
Swing frequency amplitude
Jump frequency amplitude
Swing amplitude
Aw = Fset x PB-01
Swing
Triangular
cycle
rising time
Setting Range
0: Relative to the central frequency
1: Relative to the maximum frequency
Setting Range
0.0%–100.0%
0.0%–50.0%
- 213 -
Description of Function Codes
Time (t)
Decelerate by
deceleration time
Default
0
Default
0.0%
0.0%