Function Code Table
Function
Parameter Name
Code
Backup frequency upon
P9-55
abnormality
Type of motor temperature
P9-56
sensor
Motor overheat protection
P9-57
threshold
Motor overheat warning
P9-58
threshold
Action selection at
P9-59
instantaneous power failure
Action pause judging voltage
P9-60
at instantaneous power
failure
Voltage rally judging time at
P9-61
instantaneous power failure
Action judging voltage at
P9-62
instantaneous power failure
Protection upon load
P9-63
becoming 0
Detection level of load
P9-64
becoming 0
Detection time of load
P9-65
becoming 0
P9-67
Over-speed detection value
P9-68
Over-speed detection time
Detection value of too large
P9-69
speed deviation
Detection time of too large
P9-70
speed deviation
PA-00
PID setting source
PA-01
PID digital setting
0.0%–100.0% (maximum
frequency)
0: No temperature sensor
1: PT100
2: PT1000
0–200°C
0–200°C
0: Invalid
1: Decelerate
2: Decelerate to stop
80.0%–100.0%
0.00–100.00s
60.0%–100.0% (standard bus
voltage)
0: Disabled
1: Enabled
0.0%–100.0% (rated motor
current)
0.0–60.0s
0.0%–50.0% (maximum
frequency)
0.0–60.0s
0.0%–50.0% (maximum
frequency)
0.0–60.0s
Group PA: Process Control PID Function
0: PA-01
1: AI1
2: AI2
3: AI3
4: Pulse setting (DI5)
5: Communication setting
6: Multi-reference
0.0%–100.0%
- 106 -
Setting Range
I5300 User Manual
Default
Property
100.0%
1
110°C
90°C
0
90.0%
0.50s
80.0%
0
10.0%
1.0s
20.0%
1.0s
20.0%
5.0s
0
50.0%