Description of Function Codes
Function Code
P8-03
P8-04
P8-05
P8-06
P8-07
P8-08
The I5300 provides a total of four groups of acceleration/deceleration time, that is,
the preceding three groups and the group defined by P0-17 and P0-18. Definitions of
four groups are completely the same. You can switch over between the four groups of
acceleration/deceleration time through different state combinations of DI terminals. For more
details, see the descriptions of P4-01 to P4-05.
Function Code
P8-09
Jump frequency 1
P8-10
Jump frequency 2
P8-11
Frequency jump amplitude
If the set frequency is within the frequency jump range, the actual running frequency is the
jump frequency close to the set frequency. Setting the jump frequency helps to avoid the
mechanical resonance point of the load.
The I5300 supports two jump frequencies. If both are set to 0, the frequency jump function
is disabled. The principle of the jump frequencies and jump amplitude is shown in the
following figure.
Figure 6-15 Principle of the jump frequencies and jump amplitude
Output
frequency (Hz)
Jump
frequency 2
Jump
frequency 1
Parameter Name
Acceleration time 2
Deceleration time 2
Acceleration time 3
Deceleration time 3
Acceleration time 4
Deceleration time 4
Parameter Name
Frequency jump amplitude
Frequency jump amplitude
Setting Range
0.0–6500.0s
0.0–6500.0s
0.0–6500.0s
0.0–6500.0s
0.0–500.0s
0.0–6500.0s
Setting Range
0.00 Hz to maximum frequency
0.00 Hz to maximum frequency
0.00 Hz to maximum frequency
Frequency jump amplitude
Frequency jump amplitude
Time (t)
- 188 -
I5300 User Manual
Default
Model dependent
Model dependent
Model dependent
Model dependent
Model dependent
Model dependent
Default
0.00 Hz
0.00 Hz
0.00 Hz