Function Code Table
Function
Parameter Name
Code
Stator resistance
P1-06
(asynchronous motor)
Rotor resistance
P1-07
(asynchronous motor)
Leakage inductive reactance
P1-08
(asynchronous motor)
Mutual inductive reactance
P1-09
(asynchronous motor)
No-load current
P1-10
(asynchronous motor)
Stator resistance
P1-16
(synchronous motor)
Shaft D inductance
P1-17
(synchronous motor)
Shaft Q inductance
P1-18
(synchronous motor)
Back EMF (synchronous
P1-20
motor)
Encoder pulses per
P1-27
revolution
P1-28
Encoder type
A/B phase sequence of ABZ
P1-30
incremental encoder
Setting Range
0.001–65.535 Ω (AC drive power
≤ 55 kW)
0.0001–6.5535 Ω (AC drive
power > 55 kW)
0.001–65.535 Ω (AC drive power
≤ 55 kW)
0.0001–6.5535 Ω (AC drive
power > 55 kW)
0.01–655.35 mH (AC drive power
≤ 55 kW)
0.001–65.535 mH (AC drive
power > 55 kW)
0.1–6553.5 mH (AC drive power
≤ 55 kW)
0.01–-655.35 mH (AC drive
power > 55 kW)
0.01 to P1-03 (AC drive power ≤
55 kW)
0.1 to P1-03 (AC drive power >
55 kW)
0.001–65.535 Ω (AC drive power
≤ 55 kW)
0.0001–6.5535 Ω (AC drive
power > 55 kW)
0.01–655.35 mH (AC drive power
≤ 55 kW)
0.001–65.535 mH (AC drive
power > 55 kW)
0.01–655.35 mH (AC drive power
≤ 55 kW)
0.001–65.535 mH (AC drive
power > 55 kW)
0.1–6553.5 V
1–65535
0: ABZ incremental encoder
1: UVW incremental encoder
2: Resolver
3: SIN/COS encoder
4: Wire-saving UVW encoder
0: Forward
1: Reserve
- 84 -
I5300 User Manual
Default
Property
Model
dependent
Model
dependent
Model
dependent
Model
dependent
Model
dependent
Model
dependent
Model
dependent
Model
dependent
Model
dependent
1024
0
0