IACDRIVE I5300 Series User Manual page 211

Ac drive
Table of Contents

Advertisement

I5300 User Manual
Figure 6-28 PID parameters switchover
PA-05, PA-06, PA-07
PA-15, PA-16, PA-17
Function Code
PA-21
PID initial value
PA-22
PID initial value holding time
When the AC drive starts up, the PID starts closed-loop algorithm only after the PID output
is fxed to the PID initial value (PA-21) and lasts the time set in PA-22.
Figure 6-29 PID initial value function
Function Code
Maximum deviation between two PID
PA-23
outputs in forward direction
Maximum deviation between two PID
PA-24
outputs in reverse direction
This function is used to limit the deviation between two PID outputs (2 ms per PID output) to
suppress the rapid change of PID output and stabilize the running of the AC drive.
PA-23 and PA-24 respectively correspond to the maximum absolute value of the output
deviation in forward direction and in reverse direction.
PI
parameters
Group 1 of PID
parameters
Group 2 of PID
parameters
PA-19
Parameter Name
Output
frequency
PID initial value
PA-21
PID initial value
holding time PA -22
Parameter Name
Description of Function Codes
PID deviation
PA-20
Setting Range
0.0%–100.0%
0.00–650.00s
Time
Setting Range
0.00%–100.00%
0.00%–100.00%
- 211 -
Default
0.0%
0.00s
Default
1.00%
1.00%