Figure 6-20 Acceleration/deceleration time switchover
frequency (Hz)
Set frequency
During acceleration, if the running frequency is smaller than the value of P8-25, acceleration
time 2 is selected. If the running frequency is larger than the value of P8-25, acceleration
time 1 is selected.
During deceleration, if the running frequency is larger than the value of P8-26, deceleration
time 1 is selected. If the running frequency is smaller than the value of P8-26, deceleration
time 2 is selected.
Function Code
P8-27
It is used to set whether terminal JOG is preferred.
If terminal JOG is preferred, the AC drive switches to terminal JOG running state when there
is a terminal JOG command during the running process of the AC drive.
Function Code
P8-28
Frequency detection value (FDT2)
Frequency detection hysteresis
P8-29
(FDT hysteresis 2)
The frequency detection function is the same as FDT1 function. For details, refer to the
descriptions of P8-19 and P8-20.
Function Code
Any frequency reaching
P8-30
detection value 1
Any frequency reaching
P8-31
detection amplitude 1
Any frequency reaching
P8-32
detection value 2
Output
P8-25
P8-26
Acceleration
time 2
Acceleration
time 1
Parameter Name
Terminal JOG preferred
Parameter Name
Parameter Name
Description of Function Codes
Deceleration
time 2
Deceleration
time 1
Setting Range
0: Disabled
1: Enabled
Setting Range
0.00 to maximum
frequency
0.0%–100.0% (FDT2
level)
Setting Range
0.00 Hz to maximum
frequency
0.0%–100.0% (maximum
frequency)
0.00 Hz to maximum
frequency
- 193 -
Time (t)
Default
0
Default
50.00 Hz
5.0%
Default
50.00 Hz
0.0%
50.00 Hz