Description of Function Codes
Function Code
P4-28
Pulse minimum input
Corresponding setting of
P4-29
pulse minimum input
P4-30
Pulse maximum input
Corresponding setting of
P4-31
pulse maximum input
P4-32
Pulse filter time
These parameters are used to set the relationship between DI5 pulse input and
corresponding settings. The pulses can only be input by DI5. The method of setting this
function is similar to that of setting AI1 function.
Function Code
P4-33
The unit's digit, ten's digit and hundred's digit of this parameter are respectively used to
select the corresponding curve of AI1, AI2 and AI3. Any of the five curves can be selected
for AI1, AI2 and AI3.
Curve 1, curve 2 and curve 3 are all 2-point curves, set in group P4. Curve 4 and curve 5
are both 4-point curves, set in group A6.
The I5300 provides two AI terminals as standard. AI3 is provided by an optional extension
card.
Function Code
Setting for AI less
P4-34
than minimum input
Parameter Name
Parameter Name
AI curve selection
Parameter Name
Setting Range
0.00 kHz to P4-30
-100.00%–100.0%
P4-28 to 50.00 kHz
-100.00%–100.0%
0.00–10.00s
Setting Range
Unit's digit (AI1 curve selection)
Curve 1 (2 points, see P4-13 to P4-16)
Curve 2 (2 points, see P4-18 to P4-21)
Curve 3 (2 points, see P4-23 to P4-26)
Curve 4 (4 points, see A6-00 to A6-07)
Curve 5 (4 points, see A6-08 to A6-15)
Ten's digit (AI2 curve selection)
Curve 1 to curve 5 (same as AI1)
Hundred's digit (AI3 curve selection)
Curve 1 to curve 5 (same as AI1)
Setting Range
Unit's digit (Setting for AI1 less than
minimum input)
0: Minimum value
1: 0.0%
Ten's digit (Setting for AI2 less than
minimum input)
0, 1 (same as AI1)
Hundred's digit (Setting for AI3 less
than minimum input)
0, 1 (same as AI1)
- 170 -
I5300 User Manual
Default
0.00 kHz
0.0%
50.00 kHz
100.0%
0.10s
Default
321
Default
000