Chapter 3 Mechanical And Electrical Installation; Mechanical Installation - IACDRIVE I5300 Series User Manual

Ac drive
Table of Contents

Advertisement

Mechanical and Electrical Installation

Chapter 3 Mechanical and Electrical Installation

3.1 Mechanical Installation

3.1.1 Installation Environment Requirements
Item
Ambient temperature
Heat dissipation
Mounting location
Vibration
Protective enclosure
3.1.2 Installation Clearance Requirements
The clearance that needs to be reserved varies with the power class of the I5300, as
shown in the following figure.
Figure 3-1 Clearance around the I5300 for installation
B
A
B
-10°C to +50°C
Install the AC drive on the surface of an incombustible object, and
ensure that there is sufficient space around for heat dissipation.
Install the AC drive vertically on the support using screws.
Free from direct sunlight, high humidity and condensation
Free from corrosive, explosive and combustible gas
Free from oil dirt, dust and metal powder
Less than 0.6 g
Far away from the punching machine or the like
The I5300 series AC drives of plastic housing are the whole unit
built-in products operated through remote control and need to be
installed in the final system.The final system must have the required
fireproof cover, electrical protective cover and mechanical protective
cover, and satisfy the regional laws & regulations and related IEC
requirements.
Hot air
A
The AC drive shall be installed vertically upward .
Cold air
Requirements
Installation clearance requirements on
the I5300 series AC drives of different
power classes
Power Class
Clearance Requirements
0.7
15 kW
A ≥ 10 mm
18.5
22 kW
A ≥ 10 mm
22
37 kW
A ≥ 50 mm
37
90 kW
A ≥ 50 mm
- 30 -
I5300 User Manual
B ≥ 100 mm
B ≥ 200 mm
B ≥ 200 mm
B ≥ 300 mm