Function Code Table
Function
Parameter Name
Code
Time proportion of S-curve
P6-08
start segment
Time proportion of S-curve
P6-09
end segment
P6-10
Stop mode
Initial frequency of stop DC
P6-11
braking
Waiting time of stop DC
P6-12
braking
P6-13
Stop DC braking current
P6-14
Stop DC braking time
P6-15
Brake use ratio
P7-01
MF.K Key function selection
P7-02
STOP/RESET key function
LED display running
P7-03
parameters 1
0.0% to (100.0% – P6-09)
0.0% to (100.0% – P6-08)
0: Decelerate to stop
1: Coast to stop
0.00 Hz to maximum frequency
0.0–36.0s
0%–100%
0.0–36.0s
0%–100%
Group P7: Operation Panel and Display
0: MF.K key disabled
1: Switchover between operation
panel control and remote
command control (terminal or
communication)
2: Switchover between forward
rotation and reverse rotation
3: Forward JOG
4: Reverse JOG
0: STOP/RESET key enabled
only in operation panel control
1: STOP/RESET key enabled in
any operation mode
0000–FFFF
Bit00: Running frequency 1 (Hz)
Bit01: Set frequency (Hz)
Bit02: Bus voltage (V)
Bit03: Output voltage (V)
Bit04: Output current (A)
Bit05: Output power (kW)
Bit06: Output torque (%)
Bit07: DI input status
- 96 -
Setting Range
I5300 User Manual
Default
Property
30.0%
30.0%
0
0.00 Hz
0.0s
0%
0.0s
100%
0
1
1F