IACDRIVE I5300 Series User Manual page 95

Ac drive
Table of Contents

Advertisement

I5300 User Manual
Function
Parameter Name
Code
P5-22
DO valid mode selection
P5-23
AO1 output signal selection
P6-00
Start mode
Rotational speed tracking
P6-01
mode
Rotational speed tracking
P6-02
speed
P6-03
Startup frequency
Startup frequency holding
P6-04
time
Startup DC braking current/
P6-05
Pre-excited current
Startup DC braking time/
P6-06
Pre-excited time
Acceleration/Deceleration
P6-07
mode
Setting Range
Unit's digit (FMR valid mode)
0: Positive logic
1: Negative logic
Ten's digit (Relay 1 valid mode)
0, 1 (same as FMR)
Hundred's digit (Relay 2 valid
mode)
0, 1 (same as FMR)
Thousand's digit (DO1 valid
mode)
0, 1 (same as FMR)
Ten thousand's digit (DO2 valid
mode)
0, 1 (same as FMR)
0: Voltage signal
1: Current signal
Group F6: Start/Stop Control
0: Direct start
1: Rotational speed tracking
restart
2: Pre-excited start (asynchronous
motor)
0: From frequency at stop
1: From zero speed
2: From maximum frequency
1–100
0.00–10.00 Hz
0.0–100.0s
0%–100%
0.0–100.0s
0: Linear acceleration/
deceleration
1: S-curve acceleration/
deceleration A
2: S-curve acceleration/
deceleration B
- 95 -
Function Code Table
Default
Property
00000
0
0
0
20
0.00 Hz
0.0s
0%
0.0s
0

Advertisement

Table of Contents
loading

Table of Contents