Function Code Table
Function
Parameter Name
Code
Excitation adjustment
P2-13
proportional gain
Excitation adjustment
P2-14
integral gain
Torque adjustment
P2-15
proportional gain
Torque adjustment integral
P2-16
gain
P2-17
Speed loop integral property
Field weakening mode of
P2-18
synchronous motor
Field weakening depth of
P2-19
synchronous motor
Maximum field weakening
P2-20
current
Field weakening automatic
P2-21
adjustment gain
Field weakening integral
P2-22
multiple
P3-00
V/F curve setting
P3-01
Torque boost
Cut-off frequency of torque
P3-02
boost
Multi-point V/F frequency 1
P3-03
( 1)
F
Multi-point V/F voltage 1
P3-04
(V1)
Setting Range
0–20000
0–20000
0–20000
0–20000
Unit's digit: integral separation
0: Disabled
1: Enabled
0: No field weakening
1: Direct calculation
2: Automatic adjustment
50%–500%
1%–300%
10%–500%
2–10
Group F3: V/F Control Parameters
0: Linear V/F
1: Multi-point V/F
2: Square V/F
3: 1.2-power V/F
4: 1.4-power V/F
6: 1.6-power V/F
8: 1.8-power V/F
9: Reserved
10: V/F complete separation
11: V/F half separation
0.0% (fixed torque boost)
0.1%–30.0%
0.00 Hz to maximum output
frequency
0.00 Hz to P3-05
0.0%–100.0%
- 86 -
I5300 User Manual
Default
Property
2000
1300
2000
1300
0
1
100%
50%
100%
2
0
Model
dependent
50.00 Hz
0.00 Hz
0.0%

Advertisement