IACDRIVE I5300 Series User Manual page 21

Ac drive
Table of Contents

Advertisement

I5300 User Manual
Item
Overload capacity
Torque boost
V/F curve
V/F separation
Ramp mode
Standard
functions
DC braking
JOG control
Onboard multiple
preset speeds
Onboard PID
Auto voltage
regulation (AVR)
Overvoltage/
Overcurrent stall
control
Torque limit and
control
High performance
Power dip ride
Individualized
through
functions
Rapid current limit It helps to avoid frequent overcurrent faults of the AC drive.
Virtual I/Os
Timing control
Specifications
• G type: 60s for 150% of the rated current, 3s for 180% of
the rated current
• P type: 60s for 120% of the rated current, 3s for 150% of
the rated current
• Fixed boost
• Customized boost 0.1%–30.0%
• Straight-line V/F curve
• Multi-point V/F curve
• N-power V/F curve (1.2-power, 1.4-power, 1.6-power,
1.8-power, square)
Two types: complete separation; half separation
• Straight-line ramp
• S-curve ramp
Four groups of acceleration/deceleration time with the
range of 0.0–6500.0s
DC braking frequency: 0.00 Hz to maximum frequency
Braking time: 0.0–36.0s
Braking action current value: 0.0%–100.0%
JOG frequency range: 0.00–50.00 Hz
JOG acceleration/deceleration time: 0.0–6500.0s
It implements up to 16 speeds via the simple PLC function
or combination of DI terminal states.
It realizes process-controlled closed loop control system
easily.
It can keep constant output voltage automatically when the
mains voltage changes.
The current and voltage are limited automatically during
the running process so as to avoid frequent tripping due to
overvoltage/overcurrent.
It can limit the torque automatically and prevent frequent
over current tripping during the running process.
Torque control can be implemented in the CLVC mode.
Control of asynchronous motor and synchronous motor are
implemented through the high-performance current vector
control technology.
The load feedback energy compensates the voltage
reduction so that the AC drive can continue to run for a
short time.
Five groups of virtual DI/Dos can realize simple logic
control.
Time range: 0.0–6500.0 minutes
- 21 -
Product Information