I5300 User Manual
Figure 4-9 Frequency curve of direct start
Frequency (f)
P6-00 = 0 (Direct start)
Deceleration mode )
P6-04
(Startup frequency
holding time )
PP-06
(Startup DC
braking time)
(Startup frequency)
Running
command
P6-00 = 1 (Rotational speed tracking restart)
It is applicable to large-inertia load. The frequency curve in this mode is shown in the
following figure. If the load motor is still rotating due to the inertia when the AC drive
starts, this mode is used to prevent start overcurrent.
Figure 4-10 Frequency curve of rotational speed tracking restart
Frequency (f)
P6-00 = 1 (Rotational speed
tracking restart )
Initial rotational speed
of the load motor
Running
command
P6-00 = 2 (Pre-excited start)
It is applicable only to inductive asynchronous motor. The AC drive performs pre-
excitation before start, improving quick response of the motor and meeting the
requirements of short acceleration time. The frequency curve in this mode is shown in
the following figure.
Figure 4-11 Frequency curve of pre-excited start
Frequency (f)
P6-00 = 2 (Pre-excited start)
P6-07
(Acceleration/
Deceleration mode )
P6-04
(Startup frequency
holding time )
P6-06 (Pre-
excited time)
(Startup frequency)
Running
command
(Frequency
upper limit )
P6-07
(Acceleration /
1
P0-17
0
(Acceleration
time)
2
P6-03
P0-12
(Frequency
upper limit )
P0-17
(Acceleration
time)
Automatic rotational
speed tracking detection
P0-12
(Frequency
upper limit )
P0-17
(Acceleration
time)
P6-03
Operation, Display and Application Example
Frequency (f)
P0-12
P6-00 = 0 (Direct start)
Default:
P6-06 = 0.0s
P6-03 = 0.00 Hz
P6-04 = 0.0s
P6-07 = 0
Time (t)
Running
command
Frequency (f)
P6-00 = 1 (Rotational speed
tracking restart )
Initial rotational speed of
the load motor = 0
Automatic
rotational speed
tracking detection
Time (t)
Running
command
Frequency (f)
P6-00 = 2 (Pre-excited start)
Default:
P6-03 = 0.00 Hz
P6-04 = 0.0s
P6-07 = 0
P6-06 (Pre-
excited time)
Time (t)
Running
command
- 57 -
P0-12
(Frequency
upper limit)
P0-17
(Acceleration
time)
Time (t)
P0-12
(Frequency
upper limit )
P0-17
(Acceleration
time)
Time (t)
P0-12
(Frequency
upper limit )
P0-17
(Accelerati
on time)
Time (t)