IACDRIVE I5300 Series User Manual page 105

Ac drive
Table of Contents

Advertisement

I5300 User Manual
Function
Parameter Name
Code
Fault protection action
P9-49
selection 3
Fault protection action
P9-50
selection 4
Frequency selection for
P9-54
continuing to run upon fault
Setting Range
Unit's digit (User-defined fault 1,
Err27)
Same as unit's digit in P9-47
Ten's digit (User-defined fault 2,
Err28)
Same as unit's digit in P9-47
Hundred's digit (Accumulative
power-on time reached, Err29)
Same as unit's digit in P9-47
Thousand's digit (Load becoming
0, Err30)
0: Coast to stop
1: Stop according to the stop
mode
2: Continue to run at 7% of rated
motor frequency and resume
to the set frequency if the load
recovers
Ten thousand's digit (PID
feedback lost during running,
Err31)
Same as unit's digit in P9-47
Unit's digit (Too large speed
deviation, Err42)
Same as unit's digit in P9-47
Ten's digit (Motor over-speed,
Err43)
Same as unit's digit in P9-47
Hundred's digit (Initial position
fault, Err51)
Same as unit's digit inP9-47
Thousand's digit (Speed feedback
fault, Err52)
Same as unit's digit in P9-47
Ten thousand's digit: Reserved
0: Current running frequency
1: Set frequency
2: Frequency upper limit
3: Frequency lower limit
4: Backup frequency upon
abnormality
- 105 -
Function Code Table
Default
Property
00000
00000
0