I5300 User Manual
Function Code
Parameter Name
Mutual inductive
reactance
P1-09
(asynchronous motor)
No-load current
P1-10
(asynchronous motor)
The parameters in P1-06 to P1-10 are asynchronous motor parameters. These parameters
are unavailable on the motor nameplate and are obtained by means of motor auto-tuning.
Only P1-06 to P1-08 can be obtained through static motor auto-tuning. Through complete
motor auto-tuning, encoder phase sequence and current loop PI can be obtained besides
the parameters in P1-06 to P1-10.
Each time "Rated motor power" (P1-01) or "Rated motor voltage" (P1-02) is changed, the
AC drive automatically restores values of P1-06 to P1-10 to the parameter setting for the
common standard Y series asynchronous motor.
If it is impossible to perform motor auto-tuning onsite, manually input the values of these
parameters according to data provided by the motor manufacturer.
Function Code
Parameter Name
Stator resistance
P1-16
(synchronous motor)
Shaft D inductance
P1-17
(synchronous motor)
Shaft Q inductance
P1-18
(synchronous motor)
Back EMF
P1-20
(synchronous motor)
P1-16 to P1-20 are synchronous motor parameters. These parameters are unavailable on the
nameplate of most synchronous motors and can be obtained by means of "Synchronous
motor no-load auto-tuning". Through "Synchronous motor with-load auto-tuning", only the
encoder phase sequence and installation angle can be obtained.
Each time "Rated motor power" (P1-01) or "Rated motor voltage" (P1-02) is changed, the
AC drive automatically modifes the values of P1-16 to P1-20.
You can also directly set the parameters based on the data provided by the synchronous
motor manufacturer.
Function Code
P1-27
This parameter is used to set the pulses per revolution (PPR) of ABZ or UVW incremental
encoder. In CLVC mode, the motor cannot run properly if this parameter is set incorrectly.
0.1–6553.5 mH (AC drive power ≤ 55 kW)
0.01–-655.35 mH (AC drive power > 55 kW)
0.01 to P1-03 (AC drive power ≤ 55 kW)
0.1 to P1-03 (AC drive power > 55 kW)
0.001–65.535 Ω (AC drive power ≤ 55 kW)
0.0001–6.5535 Ω (AC drive power > 55 kW)
0.01–655.35 mH (AC drive power ≤ 55 kW)
0.001–65.535 mH (AC drive power > 55 kW)
0.01–655.35 mH (AC drive power ≤ 55 kW)
0.001–65.535 mH (AC drive power > 55 kW)
0.1–6553.5 V
Parameter Name
Encoder pulses per revolution
Description of Function Codes
Setting Range
Setting Range
Setting Range
1–65535
- 149 -
Default
Model
dependent
Model
dependent
Default
Model
dependent
Model
dependent
Model
dependent
Model
dependent
Default
1024