I5300 User Manual
They display the AI sampleding voltage/current value of AI. The actually used voltage/
current is obtained after linear correction to reduce the deviation between the sampled
voltage/current and the actual input voltage/current.
For actual corrected voltage, see U0-09, U0-10 and U0-11. Refer to group AC for the
correction mode.
Function Code
U0-24
It displays the linear speed of the DI5 high-speed pulse sampling. The unit is meter/minute.
The linear speed is obtained according to the actual number of pulses sampled per minute
and PB-07 (Number of pulses per meter).
Function Code
U0-27
It displays the DI5 high-speed pulse sampling frequency, in minimum unit of 1 Hz. It is the
same as U0-18, except for the difference in units.
Function Code
U0-28
It displays the data written by means of the communication address 0x1000.
Function Code
U0-29
It displays the motor running frequency measured by the encoder.
If P0-22 (Frequency reference resolution) is 1, the display range is -3200.0–3200.0 Hz.
If P0-22 (Frequency reference resolution) is 2, the display range is -320.00–320.00 Hz.
Function Code
U0-30
It displays the setting of main frequency X.
If P0-22 (Frequency reference resolution) is 1, the display range is -3200.0–3200.0 Hz.
If P0-22 (Frequency reference resolution) is 2, the display range is -320.00–320.00 Hz.
Function Code
U0-31
It displays the setting of auxiliary frequency Y.
Parameter Name
Linear speed
Parameter Name
Pulse input frequency
Parameter Name
Communication setting value
Parameter Name
Encoder feedback speed
Name
Main frequency X
Parameter Name
Auxiliary frequency Y
Description of Function Codes
-320.00–320.00 Hz
-3200.0–3200.0 Hz
0.00–320.00 Hz
0.0–3200.0 Hz
0.00–320.00 Hz
0.0–3200.0 Hz
- 243 -
Display Range
0–65535 m/min
Display Range
0–65535 Hz
Display Range
-100.00%–100.00%
Display Range
Display Range
Display Range