Figure 6-31 Reaching the set count value and designated count value
Count pulses input
Count pulses input
Designated count
value reached output
Set count value
reached output

Group PC: Multi-Reference and Simple PLC Function

The I5300 multi-reference has many functions. Besides multi-speed, it can be used as the
setting source of the V/F separated voltage source and setting source of process PID. In
addition, the multi-reference is relative value.
The simple PLC function is different from the I5300 user programmable function. Simple
PLC can only complete simple combination of multi-reference, while the user programmable
function is more practical. For details, see the descriptions of group A7.
Function Code
PC-00
PC-01
PC-02
PC-03
PC-04
PC-05
PC-06
PC-07
PC-08
PC-09
PC-10
PC-11
PC-12
PC-13
PC-14
PC-15
Multi-reference can be the setting source of frequency, V/F separated voltage and process
PID. The multi-reference is relative value and ranges from -100.0% to 100.0%.
As frequency source, it is a percentage relative to the maximum frequency. As V/F
separated voltage source, it is a percentage relative to the rated motor voltage. As process
PID setting source, it does not require conversion.
Multi-reference can be switched over based on different states of DI terminals. For details,
see the descriptions of group P4.
10
1
2
3
Pb-09 = 11
U0-12 = 11
Parameter Name
Reference 0
Reference 1
Reference 2
Reference 3
Reference 4
Reference 5
Reference 6
Reference 7
Reference 8
Reference 9
Reference 10
Reference 11
Reference 12
Reference 13
Reference 14
Reference 15
11
12
19
20 21
Pb-08 = 20
U0-12 = 20
Setting Range
-100.0%–100.0%
-100.0%–100.0%
-100.0%–100.0%
-100.0%–100.0%
-100.0%–100.0%
-100.0%–100.0%
-100.0%–100.0%
-100.0%–100.0%
-100.0%–100.0%
-100.0%–100.0%
-100.0%–100.0%
-100.0%–100.0%
-100.0%–100.0%
-100.0%–100.0%
-100.0%–100.0%
-100.0%–100.0%
- 215 -
Description of Function Codes
U0-12: Count value
1 2
U0-12 = 0
Default
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%