I5300 User Manual
Function Code
P8-12
It is used to set the time when the output is 0 Hz at transition of the AC drive forward rotation
and reverse rotation, as shown in the following figure.
Figure 6-16 Forward/Reverse rotation dead-zone time
frequency
Function Code
P8-13
It is used to set whether the AC drive allows reverse rotation. In the applications where
reverse rotation is prohibited, set this parameter to 1.
Function Code
P8-14
It is used to set the AC drive running mode when the set frequency is lower than the
frequency lower limit. The I5300 provides three running modes to satisfy requirements of
various applications.
Function Code
P8-15
This function is used for balancing the workload allocation when multiple motors are used
to drive the same load. The output frequency of the AC drives decreases as the load
increases. You can reduce the workload of the motor under load by decreasing the output
frequency for this motor, implementing workload balancing between multiple motors.
Function Code
P8-16
Parameter Name
Forward/Reverse rotation dead-zone time
Output
(Hz)
Forward
rotation
Parameter Name
Reverse control
Parameter Name
Running mode when set
frequency lower than
frequency lower limit
Parameter Name
Droop control
Parameter Name
Accumulative power-on time threshold
Description of Function Codes
Reverse
Dead-zone
rotation
time
Setting Range
0: Enabled
1: Disabled
Setting Range
0: Run at frequency lower limit
1: Stop
2: Run at zero speed
Setting Range
0.00–10.00 Hz
- 189 -
Setting Range
0.0–3000.0s
Default
0
Default
0.00 Hz
Setting Range
Default
0–65000 h
Default
0.0s
Default
0
0 h