Description of Function Codes
Function Code
P9-20
DI status upon 3rd fault
Output terminal status
P9-21
upon 3rd fault
AC drive status upon 3rd
P9-22
fault
Power-on time upon 3rd
P9-23
fault
Running time upon 3rd
P9-24
fault
P9-27
Frequency upon 2nd fault
P9-28
Current upon 2nd fault
P9-29
Bus voltage upon 2nd fault
P9-30
DI status upon 2nd fault
Output terminal status
P9-31
upon 2nd fault
P9-32
Frequency upon 2nd fault
P9-33
Current upon 2nd fault
P9-34
Bus voltage upon 2nd fault
P9-37
DI status upon 1st fault
Output terminal status
P9-38
upon 1st fault
P9-39
Frequency upon 1st fault
P9-40
Current upon 1st fault
P9-41
Bus voltage upon 3rd fault
P9-42
DI status upon 1st fault
Output terminal status
P9-43
upon 1st fault
P9-44
Frequency upon 1st fault
Parameter Name
Description
It displays the status of all DI terminals when
the latest fault occurs.
The sequence is as follows:
If a DI is ON, the setting is 1. If the DI is OFF,
the setting is 0. The value is the equivalent
decimal number converted from the DI status..
It displays the status of all output terminals
when the latest fault occurs.
The sequence is as follows:
If an output terminal is ON, the setting is 1.
If the output terminal is OFF, the setting is 0.
The value is the equivalent decimal number
converted from the DI statuses.
Reserved
It displays the present power-on time when the
latest fault occurs.
It displays the present running time when the
latest fault occurs.
Same as P9-17–P9-24.
Same as P9-17–P9-24.