IACDRIVE I5300 Series User Manual page 145

Ac drive
Table of Contents

Advertisement

I5300 User Manual
Figure 6-2 Acceleration/Deceleration time
Output frequency
(Hz)
Acceleration/Deceleration
base frequency
Set frequency
Actual acceleration time
Set acceleration time
The I5300 provides totally four groups of acceleration/deceleration time for selection. You
can perform switchover by using a DI terminal.
Group 1: P0-17, P0-18
Group 2: P8-03, P8-04
Group 3: P8-05, P8-06
Group 4: P8-07, P8-08
Function Code
P0-19
Acceleration/Deceleration time unit
To satisfy requirements of different applications, the I5300 provides three acceleration/
deceleration time units, 1s, 0.1s and 0.01s.
Modifying this parameter will make the displayed decimal places change and corresponding
acceleration/deceleration time also change.
Function Code
Frequency offset of auxiliary frequency
P0-21
source for X and Y operation
This parameter is valid only when the frequency source is set to "X and Y operation". The
final frequency is obtained by adding the frequency offset set in this parameter to the X and
Y operation result.
t1
Parameter Name
Note
Parameter Name
- 145 -
Description of Function Codes
Time (t)
Actual deceleration time
t2
Set deceleration time
Setting Range
0:1s
1: 0.1s
2: 0.01s
Setting Range
0.00 Hz to maximum
frequency (F0-10)
Default
1
Default
0.00 Hz

Advertisement

Table of Contents
loading

Table of Contents