Structure Of Function Codes - IACDRIVE I5300 Series User Manual

Ac drive
Table of Contents

Advertisement

I5300 User Manual
In Level III menu, if the parameter has no blinking digit, it means that the parameter cannot
be modified. This may be because:
Such a function code is only readable, such as, AC drive model, actually detected
parameter and running record parameter.
Such a function code cannot be modified in the running state and can only be changed
at stop.

4.3 Structure of Function Codes

The I5300, an advanced product based on I5000, groups A and U, and new function
codes to group P.
Function
Code Group
P0 to P9, PA
Standard AC drive
to PE, PP
function code group
Advanced function
A0 to A8, AC
code group
Running state
U0 to U3
function code group
In the function code display state, select the required function code by pressing the key
or
, as shown in the following figure.
Figure 4-4 Selecting the required function code
Status parameters
(Default display)
50.00
Function
Compatible with I5000 series function codes and
adding some function codes.
Multi-motor parameters, AI/AO correction, optimization
control, PLC card extension function setting.
Display of AC drive basic parameters
Level I menu
(Select the function code group )
PRG
Shift
When PP-02 = 1x
When PP-02 = x1
Operation, Display and Application Example
Description
Press
to display the
function code groups in turn .
P0
Press
to display the function
code groups in reversed turn .
PP
When PP-02 = 0x (the value
A0
of ten's digit is 0), group A is
invisible.
AC
When PP-02 = x0 (the value
of unit's digit is 0), group U is
U0
invisible.
U3
- 49 -