IACDRIVE I5300 Series User Manual page 113

Ac drive
Table of Contents

Advertisement

I5300 User Manual
Function
Parameter Name
Code
PD-03
Response delay
PD-04
Communication timeout
Modbus protocol selection
PD-05
and PROFIBUS-DP data
format
Communication reading
PD-06
current resolution
CANlink communication
PD-08
timeout time
PE-00
User-defined function code 0
PE-01
User-defined function code 1
PE-02
User-defined function code 2
PE-03
User-defined function code 3
PE-04
User-defined function code 4
PE-05
User-defined function code 5
PE-06
User-defined function code 6
PE-07
User-defined function code 7
PE-08
User-defined function code 8
PE-09
User-defined function code 9
PE-10
User-defined function code 10
PE-11
User-defined function code 11
PE-12
User-defined function code 12
PE-13
User-defined function code 13
PE-14
User-defined function code 14
Setting Range
0–20 ms
Valid for Modbus
0.0s (invalid)
0.1–60.0s
Valid for Modbus, PROFIBUS-DP
and CANopen
Unit's digit: Modbus protocol
0: Non-standard Modbus protocol
1: Standard Modbus protocol
Ten's digit: PROFIBUS-DP data
format
0: PPO1 format
1: PPO2 format
2: PPO3 format
3: PPO5 format
0: 0.01A
1: 0.1A
0.0s: Invalid
0.1–60.0s
Group PE: User-defined Parameters
F0-00 to FP-xx
A0-00 to Ax-xx
U0-xx to U0-xx
- 113 -
Function Code Table
Default
Property
2 ms
0.0s
30
0
0
F0-10
F0-02
F0-03
F0-07
F0-08
F0-17
F0-18
F3-00
F3-01
F4-00
F4-01
F4-02
F5-04
F5-07
F6-00

Advertisement

Table of Contents
loading

Table of Contents