Description of Function Codes
Value
Function
10
RUN pause
Normally open (NO) input
11
of external fault
12
Multi-reference terminal 1
13
Multi-reference terminal 2
14
Multi-reference terminal 3
15
Multi-reference terminal 4
Terminal 1 for acceleration/
16
deceleration time selection
Terminal 2 for acceleration/
17
deceleration time selection
Frequency source
18
switchover
UP and DOWN setting
19
clear (terminal, operation
panel)
Command source
20
switchover terminal
Acceleration/Deceleration
21
prohibited
22
PID pause
23
PLC status reset
24
Swing pause
25
Counter input
26
Counter reset
27
Length count input
28
Length reset
The AC drive decelerates to stop, but the running
parameters are all memorized, such as PLC, swing
frequency and PID parameters. After this function is
disabled, the AC drive resumes its status before stop.
If this terminal becomes ON, the AC drive reports Err15
and performs the fault protection action. For more
details, see the description of P9-47.
The setting of 16 speeds or 16 other references can be
implemented through combinations of 16 states of these
four terminals.
Totally four groups of acceleration/deceleration time can
be selected through combinations of two states of these
two terminals.
The terminal is used to perform switchover between two
frequency sources according to the setting in P0-07.
If the frequency source is digital setting, the terminal
is used to clear the modification by using the UP/
DOWN function or the increment/decrement key on the
operation panel, returning the set frequency to the value
of P0-08.
If the command source is set to terminal control (P0-02
= 1), this terminal is used to perform switchover between
terminal control and operation panel control.
If the command source is set to communication control
(P0-02 = 2), this terminal is used to perform switchover
between communication control and operation panel
control.
It enables the AC drive to maintain the current frequency
output without being affected by external signals (except
the STOP command).
PID is invalid temporarily. The AC drive maintains
the current frequency output without supporting PID
adjustment of frequency source.
The terminal is used to restore the original status of
PLC control for the AC drive when PLC control is started
again after a pause.
The AC drive outputs the central frequency, and the
swing frequency function pauses.
This terminal is used to count pulses.
This terminal is used to clear the counter status.
This terminal is used to count the length.
This terminal is used to clear the length.