IACDRIVE I5300 Series User Manual page 87

Ac drive
Table of Contents

Advertisement

I5300 User Manual
Function
Parameter Name
Code
Multi-point V/F frequency 2
P3-05
(F2)
Multi-point V/F voltage 2
P3-06
(V2)
Multi-point V/F frequency 3
P3-07
(F3)
Multi-point V/F voltage 3
P3-08
(V3)
P3-09
V/F slip compensation gain
P3-10
V/F over-excitation gain
V/F oscillation suppression
P3-11
gain
Voltage source for V/F
P3-13
separation
Voltage digital setting for V/
P3-14
F separation
Voltage rise time of V/F
P3-15
separation
Voltage decline time of V/F
P3-16
separation
Stop mode selection upon
P3-17
V/F separation
Setting Range
P3-03 to P3-07
0.0%–100.0%
P3-05 to rated motor frequency
(P1-04)
Note: The rated frequencies
of motors 2, 3, and 4 are
respectively set in A2-04, A3-04,
and A4-04.
0.0%–100.0%
0%–200.0%
0–200
0–100
0: Digital setting (P3-14)
1: AI1
2: AI2
3: AI3
4: Pulse setting (DI5)
5: Multi-reference
6: Simple PLC
7: PID
8: Communication setting
100.0% corresponds to the rated
motor voltage (P1-02, A4-02, A5-
02, A6-02).
0 V to rated motor voltage
0.0–1000.0s
It indicates the time for the
voltage rising from 0 V to rated
motor voltage.
0.0–1000.0s
It indicates the time for the
voltage to decline from rated
motor voltage to 0 V.
0: Frequency and voltage
declining to 0 independently
1: Frequency declining after
voltage declines to 0
- 87 -
Function Code Table
Default
Property
0.00 Hz
0.0%
0.00 Hz
0.0%
0.0%
64
Model
dependent
0
0 V
0.0s
0.0s
0