7.9.8

Gearbox

7.9.8.1
Lubricant Level
CAUTION
Park on a flat, level surface, header on the
ground and the ground speed lever in N-
DETENT position.
DANGER
Stop engine and remove key from ignition
before leaving operator's seat for any
reason. A child or even a pet could engage
an idling machine.
a. Check the lubricant level every 50 hours as
follows:
1. Park the windrower on level ground,
shutdown the engine, and remove the key.
2. Remove plug (A). The lubricant should be
visible through the hole or slightly running
out.
Form # 169017
MAINTENANCE/SERVICE – M150 ENGINE
A
138
b. Add lubricant as follows:
1. Raise engine compartment hood to highest
position.
B
2. Remove breather cap (B), and add lubricant
until it runs out at (A). Use SAE 75W-90 API
Service
Class
Transmission Lubricant.
3. Replace plug and breather cap, and tighten.
GL-5,
E
Synthetic