SYMPTOM
Lights Dim.
Lights Do Not Light.
Turn Signals Or Indicators
Showing Wrong Direction.
No Current To Cab.

8.3 HYDRAULICS

SYMPTOM
Header Or Reel Not Lifting.
Header Or Reel Lifts But Lacks
Power.
Reel And/Or Conveyor Not
Turning.
Reel And/Or Conveyor Turns But
Lacks Power.

8.4 HEADER DRIVE

SYMPTOM
Header Drive Not Engaging.
Header Drive Lacks Power
Warning Alarm Sounds
*
See your MacDon dealer
** Refer to Windrower Technical Manual
Form # 169017
TROUBLESHOOTING
PROBLEM
High resistance in circuit or poor
ground on lights.
Defective light switch.
Burnt out light bulb
Defective light switch.
Broken wiring.
Open or defective circuit breaker.
Defective relay.
Poor ground on lights.
Reversed wires.
Circuit breaker tripped.
Broken or disconnected wire.
PROBLEM
Contaminant in relief valve.
Appropriate solenoids not being
energized by activating switch.
Relief pressure too low or
contaminant in relief valve.
Header drive switch not engaged.
Flow controls adjusted too low.
Appropriate solenoid on flow control
block not being energized.
Relief pressure too low.
PROBLEM
Header drive switch in cab not
engaged.
Appropriate solenoid not being
energized by activating switch.
Operator presence switch not
closed or faulty.
Header drive overload.
Compensator valve setting too low.
Header drive overload.
Compensator valve setting too low.
204
SOLUTION
Check the wiring circuit for a
break in a wire or a poor ground.
Contact MacDon dealer.
Replace light bulb
Contact MacDon dealer.
Check wiring for broken wire or
shorts.
Check circuit breaker
Replace relay.
Clean and tighten ground wires.
Contact MacDon dealer.
Breaker automatically resets.
Contact MacDon dealer.
SOLUTION
Clean relief valve at cylinder
control valve.
Contact MacDon dealer.
Check/adjust/clean relief valve at
cylinder control valve.
Engage switch.
Toggle speed controls on CDM
to increase flow.
Contact MacDon dealer.
Check/adjust/clean compensator
pump.
SOLUTION
Engage switch.
Contact MacDon dealer.
Occupy operator's seat or
replace switch.
Reduce ground speed.
Contact MacDon dealer.
Reduce ground speed.
Contact MacDon dealer.
Issue – June 2008
SECTION
---
*
7.12.2 to
7.12.9
*
---
7.12.11.1
---
*
---
*
SECTION
**
*
**
5.16.1
6.5.3,
6.5.4, 6.6.4
*
**
SECTION
5.16.1
*
*
6.3.6
*
6.3.6
*

Advertisement

Table of Contents
loading

This manual is also suitable for:

M200 2008M150M200