MacDon M150 2008 Operator's Manual page 222

Self-propelled windrower
Table of Contents

Advertisement

J1939 SPN
J1939
J1939
Description
SPN
Fuel Pump
Pressurizing
1347
Assembly #1
Engine Oil
Change
1378
Interval
Auxiliary
1388
Pressure
J1939 Error
1484
Control
Module
1563
Identification
Input State
Accelerator
2623
Pedal Position
System
Diagnostic
2629
Code #1
System
Diagnostic
2789
Code #1
Coolant
2981
Pressure
System
Diagnostic
3511
Code # 1
Form # 169017
M150 AND M200 ENGINE ERROR CODES
Cummins
Lamp
Engine
FMI
Color
Code
4
Amber
2374
3
Amber
272
4
Amber
271
5
162
6
162
7
Amber
281
31
Maint
649
3
Amber
297
4
Amber
298
14
Red
296
31
None
211
2
Amber
1256
3
Amber
1239
4
Amber
1241
15
None
2347
15
None
2346
3
Amber
2115
4
Amber
2116
18
Amber
2117
4
Amber
238
3
Amber
239
Cat
Engine
Cummins / Caterpillar Description
Code
Exhaust Gas Pressure Sensor Circuit - Voltage Below Normal, or
Shorted to Low Source
High Fuel Pressure Solenoid Valve Circuit – Voltage Above
Normal, or Shorted to High Source
High Fuel Pressure Solenoid Valve Circuit – Voltage Below Normal,
1779
1779
High Fuel Pressure Solenoid Valve #1 – Mechanical System Not
1779
Responding Properly or Out of Adjustment
Change Lubricating Oil and Filter – Condition Exists
Auxiliary Pressure Sensor Input # 2 Circuit - Voltage Above
Normal, or Shorted to High Source
Auxiliary Pressure Sensor Input # 2 Circuit - Voltage Below Normal,
Auxiliary Pressure Sensor Input 1 - Special Instructions
Additional Auxiliary Diagnostic Codes logged - Condition Exists
Control Module Identification Input State Error - Data Erratic,
Accelerator Pedal or Lever Position Sensor 2 Circuit - Voltage
Above Normal, or Shorted to High Source
Accelerator Pedal or Lever Position Sensor 2 Circuit - Voltage
Below Normal, or Shorted to Low Source
Turbocharger Compressor Outlet Temperature (Calculated) - Data
Valid but Above Normal Operational Range – Least Severe Level
Turbocharger Turbine Inlet Temperature (Calculated) - Data Valid
but Above Normal Operational Range – Least Severe Level
Coolant Pressure 2 Circuit - Voltage Above Normal, or Shorted to
Coolant Pressure 2 Circuit -Voltage Below Normal, or Shorted to
Coolant Pressure 2 - Data Valid but Below Normal Operational
Range - Moderately Severe Level
Sensor Supply Voltage #3 Circuit – Voltage Below Normal, or
Sensor Supply Voltage #3 Circuit – Voltage Above Normal, or
220
or Shorted to Low Source
Output current low
Output current high
or Shorted to Low Source
Intermittent, or Incorrect
High Source
Low Source
Shorted to Low Source
Shorted to High Source
Issue – June 2008

Advertisement

Table of Contents
loading

This manual is also suitable for:

M200 2008M150M200