Symptom
Keyboard
behaves
strangely
Can't leave
application
Or
Locks up
Or
Behaves
strangely
The Real Time
Clock (RTC)
gains over the
DOS clock
Report any persistent problems to your system provider.
Pressing T+C or T+W+C will often abort an application, while
T+A+D will normally reboot, but either or both may be disabled by an
application.
Pressing P will usually turn off but this may be disabled by an application.
64
Cause - remedy
A previous application has redefined the keyboard, so
that keys have different effects to normal.
- If you are in an application, leave it first (see above),
then reboot by pressing T+A+D
See also: Keyboard modes, section 7.4.3, and
International keyboards, section 5.4.5.
Program crash or hardware failure.
- Reboot by pressing T+A+D
OR if this won't work, remove and refit the battery cap
(and disconnect the charger, if connected), then turn on
again.
If normal operation resumes, carry out the checks
described in the next section.
- Finally, if you have been supplied with instructions for
the
EMERGENCY
subsequent pages), try that. If you cannot restore
normal operation, contact your technical support team
or system provider.
An application is not allowing the MP2500 to enter
Power Save mode. (The BIOS synchronises the two
clocks each time the MP2500 wakes up out of Power
Save mode.)
HARDWARE
H
MP2500 System Developer's Guide
USKY