Husky MP2500 Manual page 169

Hide thumbs Also See for MP2500:
Table of Contents

Advertisement

Configure the MP2500 as follows:
Option
Setting
Baud rate:
*
Protocol:
XON/XOFF
Length:
7
Parity:
*
Stop bits:
*
LF:
Yes
Null:
20
RTS:
-
DTR:
No
CTS:
Yes
DSR:
No
DCD:
No
Echo:
Yes
Txt/o:
1
Rxt/o:
-
Serig:
off
Configure the printer as follows:
With the 5-wire cable (TxD, RxD, CTS, RTS, 0
parity, data bits and speed as set on the MP2500, and select the
XON/XOFF protocol.
With the simple 3-wire cable (TxD, RxD, 0
select a Baud rate which is significantly slower than the printer's printing
speed. For example, if the printer prints at 40cps, select a speed of 300
Baud or less. You may need to link the printer's CTS to an active pin.
Chapter 13: Introduction to Communications
Comments
Set to suit printer. (As fast as you can, to
save time.)
Used to supplement handshaking.
ASCII data.
Set to suit printer.
Set to suit printer.
Add LFs after CRs to make the printer
advance the paper correctly.
Needed to give printer time to perform CR
LF.
Irrelevant.
Not needed.
Handshake input when transmitting, allowing
transmission to proceed. (Connected to
printer's RTS.)
Not needed.
Not needed.
To monitor progress.
This timeout will allow you to monitor
problems such as paper out or off-line.
Irrelevant as printers don't usually transmit
data.
Irrelevant.
): Set the baud rate,
Volt
): set CTS to 'No' and
Volt
147