Note: 38400 Baud is not recommended for MP2500.
226
Byte 2
Baud rate
0
110
1
150
2
300
3
600
4
1200
5
2400
6
4800
7
9600
8
19200
9
38400 (see Note below)
Byte 3
Data bits
1
7
2
8
Byte 4
Parity
0
None
1
Odd
2
Even
Byte 5
Stop bits
0
One
1
Two
Byte 6
Handshake
D7
ignored
D6=1
DCD enable
D5=1
DSR enable
D4=1
CTS enable
D3
ignored
D2=1
DTR enable
D1,D0=00
RTS off
D1,D0=01
RTS hold
D1,D0=10
RTS true
D1,D0=11
ignored