80H
Set battery capacity (APM)
81H
Control power output
85H
Set/restore power menu (APM)
89H
Get/set power management mode
8DH
Get/set boost charge (SPM)
90H
Set 5V mark/space duration
96H
Control/monitor fast discharge
9CH
FPM functions (FPM)
Read on more for more details.
Get power level (APM)
Entry
Exit
Comment
Set low power threshold (APM)
Entry
Exit
Comment
358
AH=61H
AH=level
On the FS3, this function reads the power level in APM
mode. On the MP2500, there is no APM mode and the
battery level is not monitored, so this function will
always return 7FH.
AH=62H
AL=level
BX=interval (1..0258H)
AH=status
On the FS3, this function sets the low power threshold
for APM mode. On the MP2500, there is no APM mode
so this function is ignored; instead, low power warnings
are issued when the battery voltage falls below a fixed
threshold.
H