Note that the bottom line is also used to display status and error
messages.
This screen allows you to configure two options, by selecting an option
with I or J and then pressing G or H to alter it. The options are:
Baud Rate: select the Baud rate for the transfer. You should
normally select the highest rate unless you experience problems.
Mode: set this to Active to enable transmission of the standard
XMODEM protocol characters.
The other two fields are:
Path: this will be COM2.
Record #: this will be blank until transfer begins.
When the options are set correctly, press E to start the transfer.
Initially, the status line will read POLLING.
When the host starts sending data, the status line will read LOADING
and Record # will increment as each record is received.
When transfer has finished, COMPLETED
displayed briefly, then the received program will be executed.
If any error messages are displayed, see section 14.6.3.
To cancel the transfer at any time, press C. The data which is currently
being received will be discarded and you will be returned to the DOS
prompt.