Forced Power-Down

Stop any host activity.
1.
Remove power from the library using one of the following methods:
2.
a.
b.

Lock the Robot

Make sure you have selected Prepare the Robot for removal before the library
1.
powers down (see
parks the robot in a protective housing at the top of the library.
Locate the robot lock on the back of the base module. There are two robot lock
2.
types (see below). Following the procedure for your lock type.
After locking, within the power-down dialog, select I have secured the Robot
3.
Lock in the locked position.

Lock the Knob-type Robot Lock (new version)

To lock, turn the knob counter-clockwise until it clicks into place.
The pointer on the knob should point past the red, locked padlock icon.
Moving the rack or moving the library to a new rack.
Preparing the library for shipment.
Use the forced (hard) shutdown method. Press the front panel power button
and hold it until the library shuts down (approximately 10 seconds).
Use the physical method, if the hard shutdown does not work. Remove power
from all power supplies (disconnect the power cord from all power supplies or
set the PDU or power strip switch to the off position).
"Controlled Power-Down from the Interface"
"Lock the Robot"
on page 9-3.
Power Off the Library
on page 9-2). This
Servicing the Library 9-3