Detector display this name can only contain 5 characters.
Enter the radius in mm for which balancing weights can be applied to the rotor.
The Detector uses this value to calculate a suggested test weight (see notes in
section "Balancing measurement"
calculate a suggested test weight.
Deactivate Continuous if you can attach the balancing weights anywhere on the
shaft. If this is not possible (e.g. with a fan with 10 blades), Continuous must
not be selected.
If you activated Continuous, use Discrete positions to select the number of
possible positions for the balancing weights, e.g. for a fan. In addition, please
enter the angle of the next possible position against the direction of rotation to
the reflex mark edge in Angle trigger mark -> Pos. 1. This position is called
P1.
Resonance frequency bands
In this section you can manually enter the resonant frequency bands determined
for this measuring point.
Click on
.
Enter the name of the frequency band.
Select the Start frequency and End frequency and
then click OK.
You can copy resonant frequency b ands determined from a run up/
coast down test and sub sequent creation of an amplitude/phase
diagram to the b alancing configuration (see Setup run up/coast
down
To delete frequency bands
select a frequency band .
Click on
and
confirm with Yes.
234
).
82
). If you enter 0 here, the Detector cannot
Trendline 3
71