Measuring at a pre-configured measuring point
Fix the sensor to the pre-determined point.
Start with the menu item Condition Monitoring > Select position.
If you have marked your measuring points with RFID tags (see Automatic
assignment of RFID tags to measuring points
recognizes the measuring point as soon as you move the area under the
display near to the RFID tags.
If the Detector recognizes more than one RFID tag, it displays a list
of all tags found for selection. If the configuration does not contain
one or more of the tags, the Detector displays an error message to
indicate this.
If no RFID tag is available, select then the name of the measuring point you
have fixed the sensor to using the subsequent menus.
Then mark Start measurement and
confirm your selection using the Enter key
Starting the measurement after selecting a measuring point
A measuring point that has already been measured is indicated in the menu with
the symbol
.
When all measuring points in a sub-tree of a configuration (e.g. a machine) have
been measured, this is also marked like this. Is the subtree only partially
measured, then the Detector shows the symbol
If a line in the menus is crossed out, a data error has occurred at this point. It
cannot be selected. For this, see "System messages and their meaning
well.
Are at the selected measuring point still data from the last measurement stored
in Detector, you can view the measuring results again before starting the new
measurement.
), the Detector automatically