Displaying measured values in the Viewer
You can display one or multiple measured values in the FIS Viewer.
Double-click on a measurement to view it in the Viewer.
To view multiple measured values, click the desired measured values while
holding the CTRL key.
Then double-click one of the selected measurements while holding the SHIFT
key.
To view the FFTs of one or more measured values, each in an individual
window, first select the measured values. Then right click on the selection and
then on Show FFTs in multiple windows.
To view the FFTs of one or more measured values as a waterfall graph, first
select the measured values. Then right click on the selection and on Show
FFTs as waterfall graph. In the waterfall graph you can view one or more FFTs
in different two or three-dimensional views or as a sonogram. For more
information, refer to the chapter "Waterfall graphs".
Show/hide bearing data
Click the Display bearing data for selected measurement button to display a list
of bearings assigned to this measuring point in the configuration
also assign bearings to measurements or delete assignments here. The
activation status of a bearing is indicated by the disabled checkbox. Both when
making assignments and disabling you can choose whether
bearing data should apply or not for all measurements already performed, or
only for measurements from a certain period
Add bearing
Click
and select the bearing from the bearing database.