FAG Detector III User Manual page 265

F'is trendline 3
Hide thumbs Also See for Detector III:
Table of Contents

Advertisement

Error message
Description
signals
signals but cannot as
there is not enough
memory .
Input
The v ibration signal is
ov ermodulated!
too large to be measured
by the Detector.
No RPM signal!
The rotational speed
signal is missing.
Rotational speed
The rotational speed
unstable!
signal is fluctuating.
The rotational
The acquired speed is
speed not w ithin
outside the rotational
range.
speed band defined in .
No conf. for RFID No configuration found
for the RFID entry .
Could not find at
Detected RFID tags and
least one
configured measuring
configuration
points do not match.
Multiple IDs read.
Tw o or more tags w ere
Please repeat
found w hile try ing to
assign an RFID tag.
Cause of the fault / solution
y ou hav e taken multiple measurements at this measuring
point. The characteristic v alues are alw ay s sav ed, but none
or only some of the time signals are sav ed.
There are tw o possible causes for this:
The input signal is v ery large (>50 g). Use another
sensor (w ith a sensitiv ity of 10 mV/g, for ex ample).
The strength of the signal increased after the amplifier
w as adjusted due to an impact on the machine, for
ex ample. The v ibrations must remain more or less
constant throughout the entire measurement.
Possible causes:
The trigger sensor is not correctly aligned w ith the reflex
mark.
The reflex mark w as not glued on.
The trigger sensor is too close to the reflex mark (<10
cm). Increase the distance.
The trigger sensor has been incorrectly configured
in Trendline (incorrect supply v oltage, for ex ample).
You hav e not connected the trigger sensor to the AUX
port
of the Detector.
216
Possible causes:
The trigger sensor is not correctly aligned w ith the reflex
mark.
The trigger sensor is too close to the reflex mark (should
be at least 10 cm).
Machine rotational speed fluctuates.
Reduce the speed of the machine or use the current
rotational speed as the new nominal rotational speed.
This error occurs w hen Trendline sends the RFID status for
a measuring point before a balancing, CM or run up/coast
dow n configuration w as sent. Make sure that there is a
configuration for the measuring point on the Detector. The
Trendline database may contain an error. Please contact
support@fis-serv ices.com.
The Detector found at least one RFID tag w ithout a
measuring point configuration. The missing measuring point
is therefore not offered for selection for the measurement.
The assignment is not possible as the Detector found at least
tw o tags in the RFID Reader read area. Remov e the
unnecessary RFID tags from the read area.
Detector III