Selection Of The Measuring Point - FAG Detector III User Manual

F'is trendline 3
Hide thumbs Also See for Detector III:
Table of Contents

Advertisement

2. The rotational speed is determined at the start of a CM measurement if so
specified in the Measuring point configuration
outside the defined band, the Detector displays an error message. Then you
can adopt the determined rotation speed. If no signal is measured for the
rotational speed, you can enter the speed manually.
3. If active sensors are used, the Detector initializes the sensor and measures
the bias voltage. This must reach the defined range
the Detector cancels the measurement.
4. The Detector then uses the values last transferred by the Trendline software to
initialize the PGAs in the following order: main PGA -> demodulation PGA (also
see Analog branches in the Detector
Detector defines new settings for the PGAs.
5. Measurement and determination of characteristic values:
a) The Detector measures the specified channels.
b) The time signals are used to calculate the FFT.
c) The Detector uses the FFT to calculate the characteristic values.
6. If you selected the averaging function
the measurements are repeated according to the number selected:
a) The average value of all FFT values calculated is used for FTT averaging.
This is then used as the basis for calculating the characteristic values.
b) When averaging the characteristic values, the characteristic values for each
measurement calculated first. The average value for all characteristic values
calculated is then determined (steps 5a-5c are repeated).
7. If you have set universal characteristic values in the configuration, they will be
queried sequential. The capture can be canceled by the Esc button.
8. Finally, the temperature is measured providing this has been specified in the
configuration. The measurement can be canceled by the Esc button.
9. The measured values are displayed in an overview

6.7.1 Selection of the measuring point

Using the menu Condition monitoring you decide first of all if you want to record
data at a measuring point of a pre-configured measuring route or at a new
measuring point (see "Free measurement
shows how many measurement points of the pre-configured measurement route
were already measured.
224
. If the rotational speed is
58
45
. If these values are not suitable, the
273
for this measuring point in Trendline
58
.
226
"). In the lower area a statistic
252
within 10 s. Otherwise

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents