FAG Detector III User Manual page 139

F'is trendline 3
Hide thumbs Also See for Detector III:
Table of Contents

Advertisement

program automatically adds the .csv ("comma separated variables") extension.
Click on OK to export the data.
Below is a description of the contents of the export file depending on the type of
measuring point.
Measuring point from a Cm configuration
If you export a measuring point from a CM configuration, the Trendline software
saves a general export file with details of the configuration and other files with the
time signals.
The general export file contains a line for each measurement containing the
following:
Heading
idx
State
Timestamp
Velocity
Acceleration
Demodulation
Data x
Name x
Type x
Prealarm x
Alarm x
Measuring point
export_timestamp
Comment
used_revolution
config_revolution_delta
config_revolution
Contents
Measurement identification number.
Alarm Status: 0 – no alarm, 1 – pre-alarm, 2 – main alarm
Measurement timestamp.
Ex port file w ith v elocity time signal (the signal is an acceleration signal,
see also "Time signals
271
Ex port file w ith the acceleration time signal.
Ex port file w ith the demodulation time signal.
Characteristic v alue measured
Name of characteristic v alue
Ty pe of characteristic v alue
Pre-alarm threshold in % of the main alarm threshold.
Main alarm threshold.
Name of measuring point
Ex port time
Measuring point comment
The rotational speed input by the user after the measurement. This v alue
is identical to the rotational speed actually measured until it is changed.
The max imum rotational speed dev iation set in the measuring point
configuration
The rotational speed set in the measuring point configuration.
").
269
.