Reference Run - FAG Detector III User Manual

F'is trendline 3
Hide thumbs Also See for Detector III:
Table of Contents

Advertisement

Press the Enter button
If you repeat b alancing using a b alancing configuration and the
rotational speed is outside of the selected range, the calculated
coefficients are no longer meaningful. In this case, the Detector will
display a warning and you can use the differing speed or ab ort the
measurement.
To use the differing rotational speed, confirm this b y pressing the
Enter b utton
must first perform a Trial run
To ab ort the measurement of the rotational speed, press the Esc
b utton
can, for example, b ring the machine to the correct rotational
speed b efore repeating b alancing procedure.
The rotational speed measurement is followed by the reference run

6.8.2 Reference run

To perform the reference measurement, select Reference run from the balancing
menu.
The rotational
measurement. If this falls outside the defined b and, the Detector
displays an error message.
Attach the sensors to the component and connect these to the BNC connectors
of the Detector as specified in the balancing configuration
The Detector guides you through the measurement and determines the
amplitude and phase of the vibration at the sensor positions. A bar showing
mean variance displays the stability of the values. You can reset the mean by
pressing the function button
240
to apply the rotational speed displayed.
. The coefficients can now no longer b e used; you
. The Detector jumps to the Balancing menu. Now you
speed
is
to restart mean calculation.
for all planes.