7 Special information

7.1 Characteristic values

Detector III can store up to 4 different (or same just as well) characteristic values
per measuring point. The following characteristic values can be selected:
Characte
Meaning
ristic
value
RMS v alue of v ibration v elocity
ISO 10816
Frequency range: 10 Hz to 1 kHz
Unit: mm/s
v
RMS v alue of v ibration v elocity w ith freely selectable upper and low er limiting frequency
sel
Frequency range: 0.3 Hz to 20 kHz (depending on the low pass frequency )
Unit: mm/s
a
RMS v alue of acceleration in v ibration
eff
Frequency range: 2 Hz to 20 kHz (depending on the low pass frequency )
Unit: g
RMS v alue of acceleration in v ibration w ith freely selectable upper and low er limiting
a
sel
frequency
Frequency range: 0.1 Hz to 20 kHz (depending on the low pass frequency )
Unit: g
Demodulation signal of acceleration in v ibration w ith sw itchable low -pass
d
eff
Frequency range: 0.1 Hz to 20 kHz (depending on the low pass frequency )
Unit: g
d
RMS v alue of demodulation in v ibration w ith freely selectable upper and low er limiting
sel
frequency
Frequency range: 0.1 Hz to 20 kHz (depending on the low pass frequency )
Unit: g
T
Temperature
Range: -20°C to +550°C
Unit: °C
Crest factor
Ratio betw een peak v alue and RMS v alue (Crest factor = peak v alue / RMS v alue)
Univ ersal characteristic v alue
Universal
Range: 0 to 99999
Unit: none
In addition to the aforementioned characteristic values, you can
also measure rotational speed.