System Messages And Their Meaning - FAG Detector III User Manual

F'is trendline 3
Hide thumbs Also See for Detector III:
Table of Contents

Advertisement

In b alancing measurements the last coefficient provided b y the
Trendline will b e kept, so the trial run will not b e restarted at the
next b alancing process. In amplitude/phase measurements all
measurement points that are saved to a configuration or free
measurement will b e deleted also.

6.14 System messages and their meaning

Error message
Description
Sensor error
An error occurred during
the initialization phase of
the measuring process.
With activ e sensors: the
measured bias v oltage
is not w ithin the specified
range.
Measuring point is
The current measuring
crossed out
point has a data error.
You cannot start this
measurement. If y ou try
to start the
measurement, the "CRC
error" message is
display ed.
Input
The measurement
ov ermodulated!
amplifier settings are
Please measure
optimized before the
again.
measurement is carried
out. If the strength of the
measured signal
increases after this
setting increases, the
input may become
ov ermodulated.
Connect
Before performing a
temperature
temperature
sensor and sw itch
measurement y ou w ill
it on
be prompted to connect
Cause of the fault / solution
The sensor (or sensor cable) is defectiv e or not properly
connected.
If the v oltage is not w ithin the v alid range for activ e sensors,
this may be because:
the sensor is not connected,
the sensor has short circuited,
the sensor has a defectiv e cable,
the set bias v oltages
used.
For more detailed troubleshooting, perform a ICP sensor test
261
.
If there are still measured data sav ed in the Detector, use
Trendline to collect them. Only those measurements are
transferred that do not hav e an data error. Measurements
w ith data errors are lost. The send a new configuration to
the Detector.
If this error occurs, y ou must repeat the measurement. If this
error occurs frequently y ou are probably carry ing out
measurements at a machine that is turning quite slow ly (<
120 rev olutions per minute). The Detector is not designed to
carry out these kinds of measurements.
If y ou are using a Ray tek sensor and its sw itch is ON,
sw itch it off and on again.
Detector III
are w rong for the sensor being
46
263