Measuring With Universal Characteristic Value - FAG Detector III User Manual

F'is trendline 3
Hide thumbs Also See for Detector III:
Table of Contents

Advertisement

You can now choose from three options in this menu:
The last sav ed measurement of this measuring point w ill be ov erw ritten. The time
Overwrite old
signals that belong to the last measurement w ill also be ov erw ritten.
data
Save as extra
If y ou select this item and confirm w ith the Enter button
sav ed as an additional measurement. In the Trendline softw are it appears as an
data
additional measurement of the same measuring point. The time signals are also
sav ed, w hen this is required.
Discard
The measurement is not sav ed. This corresponds to pressing the Esc button
measurement
immediately after the measurement.
Bear in mind that multiple measurements can b e saved only if
sufficient memory is availab le. If insufficient space is availab le in
the memory for additional time signals these will not b e saved,
even if the option "Always save time signals" is activated in the
configuration. If the memory no longer has the capacity to store
characteristic values it will not b e possib le to save the values
ob tained during multiple measurement.

6.7.5 Measuring with universal characteristic value

To enter a characteristic value at a selected measuring point that is not
measured by the vibration or temperature sensor, you can set up
characteristic value in the Trendline software. After the Detector recorded all
vibration values, you will be requested to enter a value for the universal
characteristic value.
Accept this value by pressing the Enter button
universal characteristic values for a measurement, they will be requested
sequentially.
232
, this measurement is
65
. If you have configured several
a universal